The installation positions of the oil filter in the hydraulic system are usually as follows:
(1) To be installed at the suction port of the pump:
A surface oil filter is generally installed on the suction line of the pump to filter out larger impurities and particles to protect the hydraulic pump. In addition, the filter capacity of the oil filter should be more than twice the pump flow rate and the pressure loss is less than 0.02MPa.
(2) Installed on the outlet oil circuit of the pump:
The purpose of installing the oil filter here is to filter out pollutants that may invade valves and other components. The filtration accuracy should be 10-15μm, and it can withstand the working pressure and impact pressure on the oil circuit, and the pressure drop should be less than 0.35MPa. At the same time, a safety valve should be installed to prevent clogging of the oil filter.
(3) Installed on the oil return line of the system: This installation plays an indirect filter role. Generally, a back pressure valve is installed in parallel with the filter. When the filter is blocked and reaches a certain pressure value, the back pressure valve opens.
(4) Install on the branch oil circuit of the system.
(5) Separate filter system: Large hydraulic system can be specially equipped with a hydraulic pump and oil filter to form an independent filter circuit.
In addition to the oil filter required by the entire system in the hydraulic system, a special oil filter is often installed in front of some important components (such as servo valves, precision throttle valves, etc.) to ensure their normal operation.