Xinxiang Shunhe Filter Equipment Co., Ltd.
+86-373-5128330

EH oil system filter TX-80

Apr 13, 2021

Gas turbine suction filter K151.73.41.39.02

Oil pump outlet filter element W.38.Z.000203

YP15C48AGF02V Power plant special filter

turbine suction filter 0508.1411T1201.AW007

Power plant special filter YP16A86JGF02V

Fine filter L3.1100B-001

HQ25.300.16Z_

YP16A86JGF03V Power plant special filter

Gas turbine suction filter C9209014

Gas turbine cellulose filter FRT111

Gas turbine suction filter DL006001

Oil motive filter HY-10-005

Fine filter HQ25.300.17Z

Fine filter w.38.z.000194

Fine filter YP15C48AGF02N

Oil motive filter 0508.1161T0101.AW010

EH oil system filter YP07H36CGF03V

Gas turbine suction filter AD3E301-02D03V/-W

EH oil pump suction filter 0508.1258T1201.AW015

1618304738993_

EH oil system filter HQ25.02Z-1

Hydraulic Return Oil Filter MSF-04S-01

HY-10-007 Hydraulic Return Oil Filter

Oil motive filter HQ25.03Z

When the filter element is blocked by contaminants or the system liquid temperature is too low, flow pulsation and other factors cause the inlet oil pressure to be 0.35MPa, the signalling device will issue a signal indication. The filter element should be replaced in time or the oil temperature should be increased. In this case, if the machine cannot be stopped immediately to deal with these faults, the bypass valve located at the lower part of the filter element will automatically open (the opening pressure of the bypass valve is 0.4MPa) to protect the filter and the hydraulic system from working normally.

The design adopts direct return to filter oil, which makes it very convenient to replace the filter element or refuel the fuel tank