Duplex filter element ZNGL02010501, used in the oil return filter of the thin oil station of the coal mill in the cement plant to filter out impurities in the oil. Filter material: stainless steel mesh, deep dirt holding, small pressure difference, fast flow rate, high filtration efficiency

The failure of self-cleaning control system causes frequent start-ups to increase the amount of cleaning water and shorten the life of the filter.
1. This kind of problem is generally caused by the parameter setting of the filter not meeting the working conditions.
2. This is mainly the problem of the cleaning pressure difference value and cleaning time interval set by the pressure difference controller. The filter cleaning system is frequently started. Generally, the control system problem can be solved by setting a larger pressure difference value and time interval.
| WU-A250x5BP | SRLF-110x20P | SZU-A160x30P |
| WU-A400x5BP | SRLF-160x20P | SZU-A250x30P |
| WU-A25x10BP | SRLF-240x20P | SZU-A400x30P |
| WU-A40x10BP | SRLF-330x20P | SZU-A25x10P |
| WU-A63x10BP | SRLF-500x20P | SZU-A40x10P |
| WU-A100x10BP | SRLF-660x20P | SZU-A63x10P |
Since the sewage contains many impurities, it is very easy to block the pilot hole, causing the solenoid valve to fail to operate or to close after being opened.
The use of electric ball valve or hydraulic solenoid valve as the drain valve completely solves the problem of easy failure of ordinary solenoid valve as a self-cleaning filter and automatic drain valve
Hot Tags: zngl02010501 power plant duplex filter element, China, suppliers, customized, quotation, for sale, Cement Plant Filter Element, Replacement For Huali Hydraulic Lubrication Filter Element, Replacement For South Lubrication Filter Element, Replacement Filter Element For Jiangsu South Lubrication NDQ 150, Replacement For SICHUAN CRUN Filter Element