Gas turbine lubricating oil station filter element, filter material: stainless steel mesh, small pressure difference, fast flow rate, and large dirt holding capacity.


Pay attention to the difficulty of the gate valve in the knob position. The gate valve is usually in the open position during maintenance, and it is selected to be closed for maintenance under unique conditions. Other valves cannot be treated as open positions for any reason. The shut-off valve must be closed during maintenance to ensure that the lubricating grease fills the sealing groove along the sealing ring.
| DFB-H330x10C | RLF-110x3P | RLF-160x5 |
| DFB-H500x10C | RLF-160x3P | RLF-240x5 |
| DFB-H660x10C | RLF-240x3P | RLF-330x5 |
| DFB-H30x20C | RLF-330x3P | RLF-500x5 |
| DFB-H60x20C | RLF-500x3P | RLF-660x5 |
| DFB-H110x20C | RLF-660x3P | RLF-850x5 |
If it is opened, the sealing grease will immediately fall into the flow path or valve cavity, resulting in saving. When the pneumatic valve is greased, the problem of grease injection is often ignored. There is no problem with the water pressure, the amount of grease and the knob position in the grease injection. However, in order to ensure the grease injection effect of the gate valve, it is occasionally necessary to open or close the gate valve to inspect the lubrication effect and make sure that the surface of the valve ball or gate is evenly lubricated.